Change Language :
The plain bearings made from iglidur UW500 were developed for underwater applications with high temperatures. Examples for this are water pumps in automotive engineering, as well as in the field of medical engineering and related sectors. Unless the underwater operation is explicitly stated, the information in this chapter describes iglidur UW500 in dry operation.
| Descriptive technical specifications | ||
|---|---|---|
| Wear resistance at +23°C | - 🟧 🟧 🟧 ⬜️ ⬜️ + | More information on wear resistance |
| Wear resistance at +90°C | - 🟧 🟧 🟧 🟧 ⬜️ + | |
| Wear resistance at +150°C | - 🟧 🟧 🟧 🟧 🟧 + | |
| Slide property | - 🟧 🟧 ⬜️ ⬜️ ⬜️ + | Coefficient of friction, dynamic, against steel: µ 0.20 - 0.36 |
| Wear resistance under water | - 🟧 🟧 🟧 🟧 🟧 + | |
| Media resistance | - 🟧 🟧 🟧 🟧 🟧 + | More information on media resistance |
| Resistant to edge pressures | - 🟧 🟧 🟧 ⬜️ ⬜️ + | |
| Resistant to shock and impact loads | - 🟧 🟧 ⬜️ ⬜️ ⬜️ + | |
| Dirt resistance | - 🟧 🟧 ⬜️ ⬜️ ⬜️ + |
iglidur UW500 can be used in applications where the continuous temperatures are +150°C. With special fastening of the bearing, these temperatures can even exceed +200°C. iglidur UW500 is one of the most temperature-resistant iglidur materials. An additional protection is required for temperatures higher than +150°C.
Temperatures, thermal expansion coefficient
| min. application temperature | Upper application temperature, long-term | Upper application temperature, short-term | In addition secure axially from |
|---|---|---|---|
| -100°C | +250°C | + 300°C | +150°C |
iglidur UW500 plain bearings can be used in a wide range of applications, both in dry operation and in liquids. Due to hydrodynamic lubrication, which can be achieved at high speeds in underwater applications, surface speeds of far more than 1.5m/s can be achieved.
Surface speeds of various iglidur materials
| Maximum surface speeds [m/s] | Rotating | Oscillating | linear |
|---|---|---|---|
| Long-term | 0.8 | 0.6 | 2.0 |
| Short-term | 1.5 | 1.1 | 3.0 |

Diagram 01: Permissible pv values for iglidur UW500 plain bearings with 1mm wall thickness in dry operation against a steel shaft, at +20°C, installed in a steel housing
X = surface speed [m/s]
Y = pressure [MPa]
The compressive strength of iglidur UW500 plain bearings decreases with increasing temperatures. Diagram 02 illustrates this relationship. The maximum recommended surface pressure represents a mechanical material parameter. Conclusions about the tribology cannot be drawn from this. Diagram 03 shows the elastic deformation of iglidur UW500 under radial loads.
Diagram 04 and 05 show the coefficient of friction of iglidur UW500 plain bearings as a function of the surface speed and the load. Friction and wear are also highly dependent on the mating partner. Ground surfaces with an average surface finish Ra of 0.1 to 0.4 are ideal.
Coefficients of friction against steel (Ra = 1μm, 50 HRC):
| iglidur® UW500 | dry | Greases | Oil | Water |
|---|---|---|---|---|
| Coefficient of friction μ | 0.20 - 0.36 | 0.09 | 0.04 | 0.04 |
Diagram 06 shows an excerpt of the results of tests with different shaft materials that were carried out with plain bearings made of iglidur UW500.
iglidur UW500 plain bearings are almost universally resistant to chemicals. They are only affected by concentrated nitric acid and sulphuric acid.
All data at room temperature [+20 °C], + resistant 0 conditionally resistant - non-resistant
| Chemicals | Resistance |
|---|---|
| Alcohols | + |
| Greases, oils without additives | + |
| Hydrocarbons | + |
| Fuels | + |
| Strong alkalines | + |
| Strong acids | + |
| Diluted alkalines | + |
| Diluted acids | + |
iglidur UW500 plain bearings are standard bearings for shafts with h-tolerance (recommended minimum h9). The bearings are designed for press-fit into a housing machined to a H7 tolerance. After installation in a housing with nominal dimensions, the inner diameter of the bearings with F10 tolerance adjusts automatically. For certain dimensions, the tolerance deviates from this depending on the wall thickness (see product range).
Important tolerances according to ISO 3547-1 after press-fit:
| Diameter d1 [mm] | Housing H7 [mm] | iglidur UW500 plain bearing F10 [mm] | Shaft h9 [mm] |
|---|---|---|---|
| up to 3mm | +0.000 +0.010 | +0.006 +0.046 | -0.025 +0.000 |
| > 3 up to 6 | +0.000 +0.012 | +0.010 +0.058 | -0.030 +0.000 |
| > 6 up to 10 | +0.000 +0.015 | +0.013 +0.071 | -0.036 +0.000 |
| > 10 up to 18 | +0.000 +0.018 | +0.016 +0.086 | -0.043 +0.000 |
| > 18 up to 30 | +0.000 +0.021 | +0.020 +0.104 | -0.052 +0.000 |
| > 30 up to 50 | +0.000 +0.025 | +0.025 +0.125 | -0.062 +0.000 |
| >50 to 80 | +0.000 +0.030 | +0.030 +0.150 | -0.074 +0.000 |
| >80 to 120 | +0.000 +0.035 | +0.036 +0.176 | -0.087 +0.000 |
| > 120 up to 180 | +0.000 +0.040 | +0.043 +0.203 | +0.000 +0.100 |